In response to our communications with the publisher, a revised version of the program was available at their download site in a short time and was functional.
#Ep evaluator 8 software
We contacted the software publisher, who was unaware of such a problem but verified that our conforming file could not be successfully imported. We tested the data import function, using several ASCII files, without success. This module adds $100 to the cost of the program.
#Ep evaluator 8 manual
Our version included the “Rapid Results Entry” feature, which speeds manual data entry when results for multiple analytes must be input for individual specimens.
#Ep evaluator 8 serial number
After a straightforward installation, the software may be used for 45 days, after which one must contact the vendor to obtain a serial number that is specific for that computer.ĭata may be entered into the program either manually or by import of ASCII text files. We installed and ran the program on several platforms (Athlon or Pentium II/III CPU), all using the Windows 98SE operating system. System requirements are modest (PC with a 486 CPU, 8 MB RAM, and 10 MB hard drive space) the operating systems supported are Windows 95, 98, or NT. 11-9 Proficiency Testing Report.This software package is designed to assist the clinical laboratory in meeting minimum regulatory requirements for method evaluation and validation. 11-7 Strategy to Pass Proficiency Testing. 11-3 Calculating the Probability of PT Failure. 10-11Ĭhapter 11 Understanding Proficiency Testing
![ep evaluator 8 ep evaluator 8](https://img.informer.com/screenshots/7032/7032278_2_3.png)
10-2 Accuracy.10-5 Reportable Range.10-7 Calibration Verification.10-8 Case Studies.10-8 Case 1: A Non-Linear Case.10-9 Case 2: Inaccurate Results.10-10 Case 3: Failures Due to Inappropriate Specifications. Interpretation of Method Comparison Results.9-2 Concepts and Definitions.9-4 Types of Method Comparison Experiments.9-14 Interpretation of Results.9-15 Case 1: A Good Example.9-16 Properties of Good Data.9-17 Report for Good Case.9-18 Case 2: Effect of Proportional Error.9-19 Case 3: Effect of Constant Error.9-20 Case 4: Effect of Random Error.9-20 Case 5: Non-Linear Pattern.9-23 Case 6: Effect of Outliers.9-24 Case 7: Effect of Extreme Range.9-25 Case 8: Effect of Range of Results.9-26 Case 9: Effect of Number of Specimens.9-28 Case 10: Effect of Poor Distribution of Results.9-29 Method Harmonization Experiment.9-30Ĭhapter 10 Interpreting Linearity Experimentsĭefinition of Some Statistical Terms.10-2 Linearity. Startup Requirements.8-2 Recurring Requirements.8-3 Before You Begin.8-4Ĭhapter 9 Interpreting Method Comparison Experiments 7-5 In the Event of QC Failure.7-5 Average of Normals.7-6Ĭhapter 8 Performance Validation Experiments 6-11 Defining Performance Standards - Case Studies. 6-11 Limits defined by Performance Standards. Performance Standards Defined.6-3 Defining PS for Established Methods.6-10 Comprehensive Approach for Defining PS.6-10 Low End Performance Standards. Total Allowable Error).5-5 QC Failure.5-6 Error Profiles.5-8 Error Budgets.5-9 Calculation of Allowable Systematic Error. 5-1 Concepts of Error.5-2 Performance Standards (i.e. Major Statistical Concepts.4-2 Statistical Terms used in Clinical Laboratories.4-8Ĭhapter 5 Understanding Error and Performance StandardsĮxperimental Error. 3-4 Performance Standards.3-5 Requirements of Other Deemed Organizations.3-5 2-4 Why include these cases in a Lab Statistics Manual?.2-4 It’s the Culture, Stupid!!.2-5Ĭhapter 3 Relevant Highlights of CLIA ‘88 Regulations i Preface for the Fifth Edition.ii History of Our Company.ii Clinical Laboratory and Standards Institute Notice.iiiĬhapter 1 Introduction Chapter 2 Effects of Bad Lab ResultsĬase of the Disappearing Patients.2-2 Case of the Congressional Hearings.2-2 Case of the Failed Hospital.2-2 Case of the Mistaken Murder Charge.2-3 How Lab Error Contributes to Higher Health care Costs.2-3 Key Role of Clinical Laboratory. Rhoads Associates A Data Innovations brandġ20 Kimball Ave, Suite 100 South Burlington, VT 05403 (800) 786-2622 and (802) 658-1955 Table of Contents PrefaceĬopyright Notice. Lab Statistics Fun and Easy A Practical Approach to Method Evaluation Fifth Editionīy David G. RhoadsĪ Practical Approach to Method Validationĭeveloping Software for the Quality-Driven Clinical Laboratory Since 1983